Specification
Model No | GY600SDVI50W/175W/1000W |
IP rating | IP66 |
Light size(mm) | 1000x120x215, 750x120x215, 515x120x215 |
Weight(kg) | 4kg,5kg,6kg |
Life | 50000hours |
Carton size(mm) | 555x325x315, 790x325x315, 1040x325x315 |
Material | Die-cast aluminum + extruded aluminum + tempered glass |
Power | 50w,70w,100w |
Input | AV100-277V ,50/60 |
Power factor | >0.9 |
Lamp Luminous Efficiency(lm/w) | 100/130 |
LED | 2835/3030 |
Color temperature | 3000K、4000K、5000K 5700K、6500K |
Working temperature | -40℃-+50℃ |
humidity | 0-90% |
Warranty | 5 years |
1. The lamps adopt two schemes of surface lighting and bat wing light distribution, which are suitable for lighting needs in different tunnels;
2. The heat dissipation design is designed according to the airflow direction, which can enhance the heat dissipation capacity and avoid dust accumulation;
3. The special sealing structure design makes the protection level of the lamp reach IP65;
4. The special mounting bracket design makes the lamps adjustable in three-dimensional space;
5. Scope of use: This lamp is mainly suitable for places that need lighting such as tunnels, underground passages, and underground parking lots;
Feature:
1 High efficiency and energy saving: The power consumption of GY series LED tunnel lights is one-fifth of that of traditional lamps, and the power saving reaches 50%-70%;
2 Super long life: the service life can reach 30,000 hours;
3. Healthy light: the light does not contain ultraviolet and infrared rays, no radiation, stable gloss, and is not affected by age; chromatic aberration;
4 Green and environmental protection: It does not contain harmful elements such as mercury and lead, and the electronic ballast in ordinary lamps and lanterns will generate electromagnetic interference;
5 to protect eyesight: DC drive, no stroboscopic, long-term use will not make eyes tired.
6 High protection level: IP65, waterproof and dustproof;
7 Sturdy and reliable: The LED light itself uses high-strength tempered glass and aluminum instead of traditional glass, which is sturdy and reliable, which is more convenient for transportation;
8 Easy to clean, the glass surface is evenly stressed, and can be washed by high-pressure water gun without breaking;
9 The shell is made of high-strength and high thermal conductivity aluminum alloy material, and the surface is oxidized.
GY600SDⅥ-surface glow
GY600SDⅥ-lens
Installation Steps:
When installing, fix the lamp on the wall first, and then connect the cable lead wire as required (with connection mark). After checking, turn on the power and the tunnel light can work. The specific installation steps are as follows:
8.1 Fix the lamp on the wall with expansion screws first, and the installation distance is as shown in the figure below;
8.2 Adjust each bracket in three-dimensional space to ensure the installation of lamps and the connection of lamp brackets
1, Unscrew the bracket slide
2, Move up and down to adjust the angle
3, Swivel bracket
8.3 Connect the tunnel light cable to the corresponding position according to the connection mark.
AC input connection identification: L N
L: Live wire N: Neutral wire : Ground wire