Technical Data Sheet
Parameter |
GY530Y290GKⅡXXX/220AC |
Light source model |
LED |
Rated power |
60~150W |
Input voltage |
AC220V/50~60Hz |
Power factor |
≥0.95 |
Lighting efficiency |
120~150Lm/W |
Color temperature |
3000K~5700K |
CRI |
Ra70(Or Ra80) |
IP Grade |
IP66 |
Glass Grade |
CLASS I |
Working temperature |
-40~50℃ |
Surface treatment |
Anti-corrosion spray |
Anti-corrosion |
Salt spray test passed |
Fixed method |
Bracket, boom (inch 4 inch thread), hook, ring |
Product dimension |
Φ350*210mm |
Net weight |
4.7Kg |
Carton dimension |
400*400*250mm |
Pcs in carton |
1 |
Advantages:
LED replacement for 200W 250W 400W HID fixtures
Energy-saving up to 80% than conventional HID systems
The luminous efficacy of light source over 135lm/w
Last 3 times longer than MHL or HID lamps
CCT range from 3000K to 5700K
Lifetime over 50,000 hours
5 years warranty
Lamps contain no lead or Mercury, ROHS compliant
Surge protection: 4KV
Suitable to use in enclosed fixtures
Item No | Name | Material |
1 | Safety cable | Stainless steel |
2 | bracket | steel |
3 | Driver | AC driver |
4 | waterproof connector | steel |
5 | lamp body | Aluminum |
6 | LED module | SMD LED chips |
7 | Reflector | PC |
8 | Seal ring | Silicon |
9 | Lens | Glass |
10 | Glass Cover Ring | Aluminum |
Installation
1. Bracket installation:
Unpacking: Open the box, take out the luminaire, check if the luminaire is in good condition, and whether the accessories are complete.
2. Fixing the lamp: Adjust the lamp bracket to rotate to the required angle, lock the angle adjustment screw and fixing bolt.
According to the hole position of the bracket, the hole is punched on the mounting surface, and the lamp is fixed on the mounting surface by bolts.
Fixing the lamp : Fix the hook or lifting ring of the lamp body to the mounting point by means of a fixing such as a wire rope or a chain (the fixing parts must be prepared by yourself).
Safety cable fixing and electrical connection: The anti-drop chain fixing and electrical connection method are the same as those described in the “bracket mounting” scheme.
3, Boom installation:
Unpacking: Open the box, take out the luminaire, check if the luminaire is in good condition, and whether the accessories are complete.
Boom installation: Screw the completed boom (the boom must be prepared) into the fixture mounting hole and the lock screw.
Safety cable fixing and electrical connection: The anti-drop chain fixing and electrical connection method are the same as those described in the “bracket mounting” scheme.
Note: The entire installation process should be carried out in the case of power failure, and all power supply can be supplied after the installation is completed.
The wire rope, chain, and boom light installation fittings are not included in the lamp, and must be prepared when installing.
Application
LED UFO High bay widely used in Warehouses, libraries, workshops, shopping malls, supermarkets, shops, restaurants, sports centers, cinemas, hospitals, clothing stores, bars, and other indoor lighting places.
Post time: Jul-17-2023